The inverter can convert the DC power into the required AC power. And within a certain time, the switching device can be turned on, off, and output, which can also play a role in protecting the circuit. For example, air conditioning, including some electric tools, as well as computers, range hoods, refrigerators, etc., household appliances need to be transformed through inverters in order to operate normally.
Lipower's inverter supports multiple sockets and various small functions for customers to use, aiming to improve their user experience
MODEL
|
INO4000A
|
INO6000A
|
||
The Rated Power
|
4000VA
|
6000VA
|
||
BATTERY
|
||||
Battery voltage
|
24 VDC
|
48VDC
|
||
Floating Charge voltage
|
27 VDC
|
54 VDC
|
||
Overcharge Protection
|
33 VDC
|
63 VDC
|
||
INPUT
|
||||
Voltage
|
230 VAC
|
|||
Selectable Voltage Range
|
170-280 VAC (For Personal Computers); 90-280VAC (For Home Appliances)
|
|||
Frequency Range
|
50Hz/60 Hz (Auto sensing)
|
|||
OUTPUT
|
||||
AC Voltage Regulation (Ball. Mode)
|
230 VAC ± 5%
|
|||
Surge Power
|
8000VA
|
12000VA
|
||
Power Factor
|
0.95
|
|||
Efficiency (Peak)
|
90% ~ 93%
|
|||
Transfer Time
|
15 ms (For Personal Computers) ; 20 ms (For Home Appliances)
|
|||
Waveform
|
Pure sine wave
|
|||
SOLAR CHARGER & AC CHARGER
|
||||
Solar Charger Type
|
MPPT
|
|||
Maximum PV Array Power
|
4000W
|
6000W
|
||
MPPT Range @ Operating Voltage
|
120-450 VDC
|
|||
Maximum PV Array Open Circuit Boltage
|
500 VDC
|
|||
Maximum Solar Charge Current
|
120 A
|
120 A
|
||
Maximum AC Charge Current
|
100 A
|
100 A
|
||
Maximum Charge Current
|
120 A
|
120 A
|
||
PHYSICAL
|
||||
Dimension, D*W*H (mm)
|
115*300*400
|
115*300*400
|
||
Net Weight (kgs)
|
9.0
|
10.0
|
||
Communication Interface
|
USB/RS232/RS485(BMS)/Local WiFi/Dry-contact
|
|||
OPERA TING ENVIRONMENT
|
||||
Humidity
|
5% to 95% Relative Humidity(Non-condensing)
|
|||
Operating Temperature
|
-10°C to 50°C
|
|||
Storage Temperature
|
-15°C to 60°C
|