Lipower's inverter supports multiple sockets and various small functions for customers to use, aiming to improve their user experience
The inverter can convert the DC power into the required AC power. And within a certain time, the switching device can be turned on, off, and output, which can also play a role in protecting the circuit. For example, air conditioning, including some electric tools, as well as computers, range hoods, refrigerators, etc., household appliances need to be transformed through inverters in order to operate normally.
MODEL
|
INO3500C
|
INO5500C
|
||
The Rated Power
|
3500VA/3500w
|
5500VA/5500w
|
||
BATTERY
|
||||
Battery voltage
|
24 VDC
|
48VDC
|
||
Floating Charge voltage
|
27 VDC
|
54 VDC
|
||
Overcharge Protection
|
32 VDC
|
64 VDC
|
||
Low battery alarming voltage
|
22 VDC
|
44 VDC
|
||
Low battery cut off protection voltage
|
21 VDC
|
42 VDC
|
||
Low battery recovery voltage
|
23 VDC
|
46 VDC
|
||
INPUT
|
||||
Voltage
|
230 VAC
|
|||
Selectable Voltage Range
|
90-280 VAC (Appliances); 170-280VAC (UPS)
|
|||
Frequency Range
|
50 Hz/60 Hz (Auto sensing)
|
|||
OUTPUT
|
||||
AC Voltage Regulation (Ball. Mode)
|
230 VAC ± 5%
|
|||
Surge Power
|
7000VA
|
11000VA
|
||
No Load Current
|
1.0A
|
1.1A
|
||
Efficiency (Peak)
|
>90%
|
|||
Transfer Time
|
10 ms (UPS) ; 20 ms (Appliances)
|
|||
Waveform
|
Pure sine wave
|
|||
MPPT SOLAR CHARGER & AC CHARGER
|
||||
Maximum PV Array Power
|
5000W
|
6000W
|
||
MPPT Range at Operating Vol.
|
120-450 VDC
|
|||
Maximum PV Array Open Circuit Vol.
|
500 VDC
|
|||
Number of MPPT Trackers/Max Output Current
|
100A
|
100A
|
||
Maximum Solar Charge Current
|
60A
|
60A
|
||
Maximum AC Charge Current
|
100 A
|
100 A
|
||
Maximum Charge Current
|
98%
|
98%
|
||
BEST PANEL CONFIGUTATION
|
||||
Best Panel Configuration
|
300Wp*9pcs*36V(2700Wp)*2Parallel
|
330Wp*9pcs*36V(2970Wp)*2 Parallel
|
||
PHYSICAL
|
||||
Dimension, D*W*H (mm)
|
481*313*117
|
481*313*117
|
||
Packing Size,D*W*H(mm)
|
543*394*204
|
|||
Net Weight (kgs)
|
9.8
|
10.5
|
||
Gross Weight(kgs)
|
11
|
11.7
|
||
OPERA TING ENVIRONMENT
|
||||
Humidity
|
5% to 95% Relative Humidity(Non-condensing)
|
|||
Operating Temperature
|
0°C to 50°C
|